Basophil Activation Test (BAT)
Basophil Degranulation Test
Method: Flow CAST® Kit (BÜHLMANN) by Flow Cytometry
Equipment: BD FACSLyric
Whole blood
Do not spin. Do not aliquot. Store specimen at 4oC. Ship on ice.
Specimen stability in Flow testing is only acceptable within 48 hours of collection if stored at 4oC, or 24 hours if stored at room temperature.
Ensure that at least four weeks have elapsed after an allergic reaction before collecting BAT.
Systemically administered antiallergenic drugs such as corticosteroids, chromoglycic acid (DSCG) should be avoided for at least 24 hours prior to blood sampling.
Interference with test results is expected for patients under omalizumab (XOLAIR®) therapy.
Walnut-specific allergen cut-off is 10%. All other listed allergens have a cutoff of 15%. These thresholds are according to the manufacturer's instructions and are applicable if the following conditions are met: Background % activation (2-2.5%), Positive control 1 and Positive control 2 % >10%. These thresholds have not been independently established or verified by the laboratory. A negative basophil activation does not rule out a possible allergy. Test results should be interpreted in conjunction with the patient's clinical presentation and the results of other relevant investigations.
Browse tests by laboratory
Customer Service
Toll Free: 1-855-381-3212
Local: 416-813-7200